Carry out a full discharge test of the emergency lights to ensure that they remain illuminated for the required duration (usually 1-3 hours). High risk task area lighting provides light for the safety of people involved in potentially dangerous processes. This lighting enables proper shut-down procedures to be followed for the safety of the operator and other occupants of a building. You need emergency lighting in areas that could be considered “dangerous” such as commercial kitchens or plant rooms. If your building has rooms larger than 60 square metres, then emergency lighting is recommended. How long do emergency lights need to stay on? The name of the person or organization responsible for the maintenance and testing of the emergency lighting system.

Confirmation that the emergency lighting system has been installed in accordance with the relevant regulations and standards. A key-switch. This is installed on the permanent live supply to an emergency fitting. When actuated it isolates the emergency fitting, thus simulating a power failure.Details of any repairs or replacements carried out on the emergency lighting system, including dates and the nature of the work carried out. An emergency log book is required to keep a record of all the testing, maintenance, and servicing carried out on an emergency lighting system. It is a legal requirement to keep an emergency log book for each building that has an emergency lighting system installed. Simulate a power failure by either an emergency key switch or by switching off the mains power to the emergency lighting. At the moment the only areas in use are reception and workshops/classrooms on ground floor (which are the areas refurbed).

Records of all testing and maintenance carried out on the emergency lighting system, including dates, results, and any faults or issues identified. It can take up to 24 hours for batteries on emergency lighting systems to recharge after a full discharge test. For businesses, testing should be planned around periods of non-occupancy – like over the weekend. In full-time tenanted buildings, other strategies may be necessary to ensure that systems work around testing times.Details of the emergency lighting system, including its location, components, and the type of system installed.

An Emergency Lighting Certificate is a document that certifies that the emergency lighting system in a building has been installed, tested and commissioned in accordance with the relevant regulations and standards. The certificate is issued by a qualified electrician or contractor who has carried out the installation and testing of the emergency lighting system. First floor has a conference room, dining area, servery and kitchen with adjourning conveniences, 11 rooms (classroom or meeting/training rooms), 5 office rooms and 3 sets of conveniences.

How is an Emergency Lighting Test Conducted?

Now the refurbishment on the ground floor seems to be wired up in the 'new' way - does not extinguish power to mains. The duration that emergency lighting should stay on for depends on the relevant regulations and standards, as well as the specific requirements of the building and its occupants. However, the general requirement is that emergency lighting should remain illuminated for a minimum of 1 hour, but it may need to remain illuminated for up to 3 hours in certain circumstances. If you have a central battery system, then most of the above still applies to you. Drop the incoming power to the battery and do the same walk tests. Make a note of any failures etc. However you need to test the whole system all at once. By testing the whole system at once, you are ensuring that the battery can power all the emergency lights for a full 3 hour duration. If you only tested in zones then the battery would not get a full and proper test. L SW is the normal mains supply. A normal light switch, or sensor, would usually be on this circuit to enable the end-user to have control over the light fitting in normal operating mode. L SW is always to be wired so that any switching of L PERM will disconnect L SW too, but any switching of L SW will not affect L PERM.

Be very careful when touching anything inside the electrical consumer box, there is a danger of electrocution if something is wrong. If in doubt seek a qualified electrician ** What time of day should I test the emergency lights Yes if you are testing/servicing on the discharge test then no lights would be a problem for persons working in those areas and so this would need doing when unoccupied - so I can see the logic behind the key switches not shutting off power - but that would only be for green LEDs and not red LEDs that would be difficult to visually see - similar if 3 tube lighting is working and one of the tubes is the EL light you wouldn't know if that EL unit was working if the main lights are still being powered... Confirmation that the emergency lighting system has been designed and installed to meet the specific requirements of the building and its occupants.

Pre-service audit

The kind of emergency lighting system your building requires depends on the nature of your business. For example, the emergency lighting system is not always required to provide light at the same intensity as the mains (however, it should be bright enough for safe evacuation). By working with the qualified engineers at Voltix Services , system designs and the ideal testing regime are all part of our compliance services . There are three widely used ways to test emergency lighting. To understand them it is necessary to understand first how an emergency light fitting is wired. Note that the remarks that follow apply to self-contained emergency fittings, not to central battery operated emergency fittings.